Skip to main content

(AFFF) Aqueous Filling Forming Foam - EngineeriSafety

Aqueous Filling Forming Foam (AFFF)

     AFFF Aqueous Filling Forming Foam contain fluorinated synthetic hydrocarbons with additional capacity even other form concentrates, of forming water solution films on the surface of inflammable liquids. These are used in concentration of 1% to 3% in water to make foam solution. This type of foams can we use on deep-seated Fires involving class 'A' and class 'B' materials.

  Aqueous  Filling Forming Foam (AFFF) of hydrocarbons and fluorocarbon surfactants to produce synthetic Firefighting foams for use as high-performance, non-polar, class B hydrocarbon fuels such as crude oil, petroleum, diesel, and aviation fuel.  Is prepared with.

AFFF Aqueous Filling Forming Foam

Aqueous Filling Forming Foam Concentrate

These concentrations can be applied with a variety of proportional and discharge devices and suppress fires through three mechanisms:
  1. Separating liquid fuel from air,
  2. Helping to prevent vapor release,
  3. Providing a cooling effect.  
   With a wide spectrum of third party approvals and listings,  SABO Foam  AFFF  provides fire fighting solutions for a variety of fixed, semi-fixed and emergency response applications.

  AFFF Concentrate has excellent wetting properties that can also withstand Class A fires effectively, and they can be used in combination with dry chemical agents to provide even greater fire extinguishing performance.  AFFF concentrations are not suitable for use on polar fuels with appreciable water solubilities such as alcohol, acetone and methyl ethyl ketone.

Uses, Discharge and Disposal of Firefighting Foam Product (USA) >>

AFFF Foam Concertrate Data sheets

Comments

Popular posts from this blog

(NRV) Non-Return Valves | Check Valves - Symbol, Types and Importance

(NRV) Non Return Valve A Non- Return Valves , check valve , clack valve, non- return valves , reflux valve, retention valve or one-way valve is a  valve that normally allows  fluid  ( liquid or gas ) to flow through it in one direction only.    Non  - Return valve/ Check valve are two-port valves, meaning that they have two openings in the body, one to enter the  fluid and the other to release the liquid. Types of (NRV) Non - Return Valves There are various types of check valves/non-return valve used in a wide variety of applications.  Non- return valves are often part of common household items.   Although they are available in a wide range of sizes and costs, Non - Return valve are generally very small, simple or inexpensive. Non - Return valve operate automatically and most are not controlled by an individual or any external control;  Accordingly, most have no valve handle or stem. The bodies (outer shells...

What are the Methods of Extinguishing Fire | Methods of Extinction and prevention

Method of Extension and Prevention: Fire depends upon a reaction between two substance and continuous because of self generated heat. There are four ways of Extinguishing fire i.e., by cooling the fuel below its ignition temperature. By cutting  off the oxygen, by cutting off the supply of fuel or by prohibiting the formation of chain carriers. This is achieved by  -  Taking away the heat faster heat it is generated. Separating the substance apart. Cooling the combustible material and its surrounding to a temperature search that fire die for want to heat. Smoothing the fire by preventing air from reaching eat or by diluting air with some inert gas ( smothering ). Starving the fire by removing combustible material fuel supply. What are the Methods of Fire Extinguishing: COOLING METHOD: Extinction by cooling is achieve, when the rate of heat generated is less than the rate the heat remove, hence the fire die water is...

21 Basic Rules of Scaffolding - Complete Guidelines on OSHA Scaffolding Safety Requirements

Complete Guideline on OSHA Scaffolding Safety Requirements Scaffolding Safety Requirements - With all of these safety practices in places, working on a scaffold can be a high without the dangerous lows.  21 Basic Rules of Scaffolding - Complete Guidelines on OSHA Scaffolding Safety Requirements. Follow the manufacturer instruction when a erecting the scaffold. Do not work on scaffold outside during strong or windy weather. Do not climb on skype old that wobble or lean to one side. Initially inspect the scaffold prior or mounting it. Do not use a scaffold if any pulley, block, hook or fitting is visible worn, cracked, rusted, or otherwise damaged. Do not use any scaffold if any rope is frayed, torn or visibly damaged. Do not use any scaffold tagged "Out of Service". Do not use unstable objects such as barrel's, boxes, loose brick or concrete block to support scaffold or planks.  Donot work on platform or scaffold unless they are fully planked. Do not use a scaffold unless...